RACK.ZN2.HP.D
Zero Nitrogen Generator
Zero Nitrogen
GC-NPD, GC-TCD, GC-AED, GC-ECD, GC-MS, Atomic absorption
The F-DGSi High Purity (HP) Nitrogen Generators are engineered to transform standard compressed air in to a safe regulated supply of 99.9995% pure nitrogen, O2 and moisture free and a catalyst to remove hydrocarbons (CH4) < 0.05 ppm from Nitrogen.
Reference : RACK-ZN2-600-HP.D

Advantages
Increased laboratory efficiency
A constant, uninterrupted gas supply of guaranteed purity eliminates interruptions of analyses to change cylinders and reduces the amount of instrument re-calibrations required.
Improved economy
Zero Nitrogen gas produced as standard
Improved safety
Zero Nitrogen produced at low pressure and ambient temperature removes the need for high pressure cylinders
Simple installation
Gas generators can be installed in the laboratory, on or under a bench, eliminating the need for long gas lines from cylinders secured elsewhere
Characteristics
- Fully regenerative PSA technology ; reduced risk of gas contamination and phthalate free
- Generates Nitrogen on demand from external compressed air
- Catalyst module for hydrocarbons level (CH4)
< 0.05 ppm - Designed to run 24 hours a day
- Smart control of the flow of inlet air, it is function of the real flow of nitrogen used by the application
- Minimum maintenance with an annual filter change
- Remote PC monitoring via USB/RS232
- Ultra fast start-up time and fast purity
- Compact and modular design
Specifications
MODELS | RACK-ZN2-600-HP.D |
---|---|
GENERALS INFORMATIONS | |
Flow rate (max) | 600 cc/min |
Outlet pressure (min) | 1 bar (14 psi) |
Outlet pressure (max) | Inlet pressure – 2 bar (29 psi) |
Nitrogen purity | > 99.9995% (< 5ppm O2 @ 7 Bar (101 psi) inlet pressure) |
Hydrocarbon content (CH4 free) | < 0.05 ppm |
AIR INLET | |
Air inlet requirement | Particulate : < 1 micron |
Dew Point : -40°C (-40°F) | |
Oil < 0.01 mg/m3 | |
Flow rate (max) | 15 L/min |
Supply pressure (min – max) | 7 bar (101 psi) – 10 bar (145 psi) |
Temperature (min – max) | 1°C (34°F) – 35°C (95°F) |
COMMUNICATION | |
LCD digital screen | LCD digital screen (operating parameters, system status, alarms) with LED indicators (Power on/off; ready or errors) |
USB/PC Control | In series |
RS232/RS485 | Option |
GENERAL DATA | |
Power consumption | 240 VA |
Electrical supply | 220 – 240 V ac / 1 ph / 50 – 60 Hz |
110 – 120 V ac / 1 ph / 50 – 60 Hz | |
Dimensions (W x H x D) | Standard 19″ Rack 5U – deep 48 cm |
CONNECTIONS | |
Outlet port | G 1/4“ Female |
OPERATING CONDITIONS | |
Temperature | From 5 – 35°C (41 – 95°F) and humidity 80% to 25°C (77°F) |
Noise | < 25 dB(A) |
IP rating | IP20 |
Pollution degree rating | 2 (with no aromatic compounds) |
Altitude | < 2000 m |