CUV_V
Gas tank
Ideal for a greater gas homogenisation and for storage gas
Buffer vessel insure a constant pressure in case of strong variation of the demand. They also avoid a permanent functioning of the compressor and allow a supply security. It also separate the condensates of the compressed air. An appropriate sizing and an anticorrosion protection reliable are indispensable.
Buffer vessel are recommended for :
• Gas supply for the instrumentation with sensitive pressure
• The storage of incoming nitrogen from a nitrogen generator
• Any other instrument requiring occasionally high flow of compressed gas which exceeds the normal gas capacity of the generator

Advantages
Cost cutting of maintenance
From part our experience feedback we consider that the time of functioning is divided by two at least : When a buffer vessel is connected after a nitrogen generator, this one will work 4000 hour per year instead of 8500 hour if it is used 24H/24H. To protect the system and its continuity, it is essential to realize a maintenance every 4000 hours (replacement of filters,
silencer) and a more evolved maintenance all the 10000 hours (compressors replacement). We thus reach 2 visits of maintenances in one year period. With the tank, we shall have to realize a single annual maintenance and push away the maintenance evolved in one year (we save money). Furthermore, there will be less stop of analysis for reasons of maintenance.
Reduction of the mechanical life of the device and increase of the life of the
Generator or compressor, if we consider 5 years, the system will have more of 40000 hours of functioning.
As any mechanical systems, such as cars, dysfunctions are going to increase due to a natural mechanical fatigue. With a reservoir plug we push away these dysfunctions.
Reduction of the noise
Certainly device possesses a sound volume of 55dB, but this mechanical noise becomes long-term unpleasant. Stops repeated by the generator or the compressor will stop the constant noise and the working conditions will be improved.
Reduction of the calorific release
Any device have a calorific release in functioning. In a room, the temperature quickly rises and only the addition of an air conditioning can make lower the ambient temperature, where from a not insignificant cost. With the stop of the device, we have no more this release of nonstop heat which allows lowering the ambient temperature. We are anxious to remind you that the nominal temperatures of functioning is situated between +15 and 35°C at the risk of degrading the system.
Characteristics
- Main Equipments Every reservoir is delivered with its accessories :
- Manometer
- Purge valve
- Safety valve - Technical characteristics :
- CE Standard
- Temperature : 50°C
- Capacity : 10 to 2000L
- Maxi Pressure : 10.7 bars
Specifications
mm |
Ø |
||||||||||||||
Volume |
PS (bar) | De | H | A | B | C | D | 1 | 2-3 | 4-5 | 6 | 7 | 8 | Weight (Kg) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
100 L | 11 | 400 | 1055 | 80 | 345 | 695 | 795 | 2″ | 1″ | 1″ | 2″ | 3/8″ | 3/8″ | 45 | |
200 L | 11 | 480 | 1455 | 88 | 343 | 1083 | 1183 | 2″ | 1″ | 1″ | 2″ | 3/8″ | 3/8″ | 65 | |
270 L | 11 | 500 | 1777 | 150 | 410 | 1330 | 1330 | 2″ | 1″ | 1″ | 2″ | 3/8″ | 3/8″ | 81 | |
500 L | 11 | 650 | 1832 | 140 | 455 | 1255 | 1255 | 2″ | 2″ | 2″ | 2″ | 3/8″ | 3/4″ | 149 | |
710 L | 11 | 800 | 1779 | 117 | 470 | 1220 | 1220 | 2″ | 2″ | 2″ | 2″ | 3/8″ | 3/4″ | 226 | |
900 L | 11 | 800 | 2129 | 117 | 470 | 1370 | 1370 | 2″ | 2″ | 2″ | 2″ | 3/8″ | 3/4″ | 262 | |
1000 L | 10.67 | 800 | 2323 | 96 | 518 | 1568 | 1568 | 2″ | 2″ | 2″ | 2″ | 3/8″ | 3/4″ | 192 | |
1500 L | 10.67 | 950 | 2463 | 80 | 569 | 1468 | 1468 | 2″ | 2″ | 2″ | 2″ | 3/8″ | 3/4″ | 284 | |
2000 L | 10.67 | 1100 | 2535 | 75 | 595 | 1495 | 1495 | 2″ | 2″ | 2″ | 2″ | 3/8″ | 3/4″ | 384 |
Other Vertical Buffer vessel available -> Capacity : 25L
Dimensions : High : 350 mm / Diameter : 300 mm
Other Vertical Buffer vessel available -> Capacity : 50L
Dimensions : High: 925 mm / Diameter : 300 mm
Connections :
1 : Drain connection
2 : Air Inlet or Air outlet or plug
3 : Air Inlet or Air outlet or plug
4 : Air Inlet or Air outlet or plug
5 : Air Inlet or Air outlet or plug
6 : High point (outlet, safety valve or plug)
7 : Manometer connection
8 : Safety valve connection