Choose serial type

CUV_V

Gas tank

Gas tanks
Standard buffer

Ideal for a greater gas homogenisation and for storage gas

Buffer vessel insure a constant pressure in case of strong variation of the demand. They also avoid a permanent functioning of the compressor and allow a supply security. It also separate the condensates of the compressed air. An appropriate sizing and an anticorrosion protection reliable are indispensable.

 

Buffer vessel are recommended for :

• Gas supply for the instrumentation with sensitive pressure
• The storage of incoming nitrogen from a nitrogen generator
• Any other instrument requiring occasionally high flow of compressed gas which exceeds the normal gas capacity of the generator

Advantages

 

Cost cutting of maintenance

From part our experience feedback we consider that the time of functioning is divided by two at least : When a buffer vessel is connected after a nitrogen generator, this one will work 4000 hour per year instead of 8500 hour if it is used 24H/24H. To protect the system and its continuity, it is essential to realize a maintenance every 4000 hours (replacement of filters,
silencer) and a more evolved maintenance all the 10000 hours (compressors replacement). We thus reach 2 visits of maintenances in one year period. With the tank, we shall have to realize a single annual maintenance and push away the maintenance evolved in one year (we save money). Furthermore, there will be less stop of analysis for reasons of maintenance.

 

Reduction of the mechanical life of the device and increase of the life of the

Generator or compressor, if we consider 5 years, the system will have more of 40000 hours of functioning.
As any mechanical systems, such as cars, dysfunctions are going to increase due to a natural mechanical fatigue. With a reservoir plug we push away these dysfunctions.

 

Reduction of the noise

Certainly device possesses a sound volume of 55dB, but this mechanical noise becomes long-term unpleasant. Stops repeated by the generator or the compressor will stop the constant noise and the working conditions will be improved.

 

Reduction of the calorific release

Any device have a calorific release in functioning. In a room, the temperature quickly rises and only the addition of an air conditioning can make lower the ambient temperature, where from a not insignificant cost. With the stop of the device, we have no more this release of nonstop heat which allows lowering the ambient temperature. We are anxious to remind you that the nominal temperatures of functioning is situated between +15 and 35°C at the risk of degrading the system.

Characteristics

  • Main Equipments Every reservoir is delivered with its accessories :
    - Manometer
    - Purge valve
    - Safety valve
  • Technical characteristics :
    - CE Standard
    - Temperature : 50°C
    - Capacity : 10 to 2000L
    - Maxi Pressure : 10.7 bars

Specifications

 

CUV_V Specifications

mm

Ø

Volume

PS (bar) De H A B C D 1 2-3 4-5 6 7 8 Weight (Kg)
100 L 11 400 1055 80 345 695 795 2″ 1″ 1″ 2″ 3/8″ 3/8″ 45
200 L 11 480 1455 88 343 1083 1183 2″ 1″ 1″ 2″ 3/8″ 3/8″ 65
270 L 11 500 1777 150 410 1330 1330 2″ 1″ 1″ 2″ 3/8″ 3/8″ 81
500 L 11 650 1832 140 455 1255 1255 2″ 2″ 2″ 2″ 3/8″ 3/4″ 149
710 L 11 800 1779 117 470 1220 1220 2″ 2″ 2″ 2″ 3/8″ 3/4″ 226
900 L 11 800 2129 117 470 1370 1370 2″ 2″ 2″ 2″ 3/8″ 3/4″ 262
1000 L 10.67 800 2323 96 518 1568 1568 2″ 2″ 2″ 2″ 3/8″ 3/4″ 192
1500 L 10.67 950 2463 80 569 1468 1468 2″ 2″ 2″ 2″ 3/8″ 3/4″ 284
2000 L 10.67 1100 2535 75 595 1495 1495 2″ 2″ 2″ 2″ 3/8″ 3/4″ 384

 

Other Vertical Buffer vessel available -> Capacity : 25L

Dimensions : High : 350 mm / Diameter : 300 mm

Other Vertical Buffer vessel available -> Capacity : 50L

Dimensions : High: 925 mm / Diameter : 300 mm

 

Connections :

1 : Drain connection

2 : Air Inlet or Air outlet or plug

3 : Air Inlet or Air outlet or plug

4 : Air Inlet or Air outlet or plug

5 : Air Inlet or Air outlet or plug

6 : High point (outlet, safety valve or plug)

7 : Manometer connection

8 : Safety valve connection

Setup guide
User manual
Missing an information ?